A Lower Extremity Neuromusculoskeletal Human Simulator

Investigators
Kevin Shelburne
Contact info (email)
kevin.shelburne@du.edu
1. Define context(s)
aid in FDA decision making
aid in clinical decision making
aid in clinical trial design
identify/explore new therapies
Current Conformance Level / Target Conformance Level
Adequate
Primary goal of the model/tool/database

Simulation of human activity for understanding normal musculoskeletal function, pathology, and treatment.

Biological domain of the model
Human musculoskeletal system
Structure(s) of interest in the model
cartilage, ligament, muscle, tendon, bone, fat
Spatial scales included in the model
mm (e.g. cartilage) to m (e.g. whole-body) to human cohorts
Time scales included in the model
millisecond to minutes
2. Data for building and validating the model
Data for building the model Published? Private? How is credibility checked? Current Conformance Level / Target Conformance Level
in vitro (primary cells cell, lines, etc.)
ex vivo (excised tissues) Y Y Adequate
in vivo pre-clinical (lower-level organism or small animal)
in vivo pre-clinical (large animal)
Human subjects/clinical y Y Adequate
Other: ________________________
Data for validating the model Published? Private? How is credibility checked? Current Conformance Level / Target Conformance Level
in vitro (primary cells cell, lines, etc.)
ex vivo (excised tissues)
in vivo pre-clinical (lower-level organism or small animal)
in vivo pre-clinical (large animal)
Human subjects/clinical
Other: ________________________
3. Validate within context(s)
Who does it? When does it happen? How is it done? Current Conformance Level / Target Conformance Level
Verification PI and staff
Validation PI and outside reviewers Year 3 and 4 recreate models and simulations to match in vivo data Adequate
Uncertainty quantification
Sensitivity analysis
Other:__________
Additional Comments
4. Limitations
Disclaimer statement (explain key limitations) Who needs to know about this disclaimer? How is this disclaimer shared with that audience? Current Conformance Level / Target Conformance Level
lower extremity musculoskeletal only users and evaluators publication adequate
5. Version control
Current Conformance Level / Target Conformance Level
Partial
Naming Conventions? Repository? Code Review?
individual modeler TBD
within the lab
collaborators
6. Documentation
Current Conformance Level / Target Conformance Level
Code commented? Adequate
Scope and intended use described? Adequate
User’s guide? TBD
Developer’s guide?
7. Dissemination
Current Conformance Level / Target Conformance Level
Adequate
Target Audience(s): “Inner circle” Scientific community Public
Simulations SimTK.org, Digital Commons
Models SimTK.org, Digital Commons
Software SimTK.org, Digital Commons
Results publication
Implications of results publication
8. Independent reviews
Current Conformance Level / Target Conformance Level
TBD
Reviewer(s) name & affiliation:
When was review performed?
How was review performed and outcomes of the review?
9. Test competing implementations
Current Conformance Level / Target Conformance Level
TBD
Yes or No (briefly summarize)
Were competing implementations tested?
Did this lead to model refinement or improvement?
10. Conform to standards
Current Conformance Level / Target Conformance Level
Partial
Yes or No (briefly summarize)
Are there operating procedures, guidelines, or standards for this type of multiscale modeling? Partially and in process of development
How do your modeling efforts conform?